ITEMS ARE STOCKED IN OUR WAREHOUSES BASED ON REGIONAL DEMAND. IF AN ITEM IS NOT IN STOCK AT A LOCAL WAREHOUSE, ADDITIONAL CHARGES MAY APPLY. X - WARNINGCancer Causing See www.P65Warnings.ca.gov Y - WARNINGReproductive Harm Z - WARNING Cancer and Reproductive Harm AWNINGS & ACCESSORIES CAMPSITE LIVING SERVICE & MAINTENANCE FRESH WATER LP GAS HEATING & COOLING GRILLING & CAMPWARE CLEANERS & WAXES ROOFING & SEALANTS SANITATION APPLIANCES ELECTRICAL ELECTRONICS VENTS & SKYLIGHTS LADDERS & STEPS TOWING TIRES, BRAKES & WHEELS LIGHTING HARDWARE COVERS JACKS & LEVELERS HITCHES GENERATOR & POWER SOLUTIONS 350 HEATING & COOLING CLIMATE CONTROL SOLUTIONS 9430E7153 9430A717 8430A6301 9430720 372034551 382034551 AIR FILTERS MERV 6 Precision, press-fit alignment to Coleman-Mach ducted ceiling assemblies Size: 16.6"x 6" Woven Filter Fabric Captures large particles: Lint, household dust, pollen, dust mites, pet dander and mold spores Replacement frequency: 90-days of use RATING 2 PACK Coleman-Mach Climate Control Accessories AIR FILTERS MERV 6 Precision, press-fit alignment to Coleman-Mach non-ducted ceiling assemblies Size: 15.9"x 4.2" Woven Filter Fabric Captures large particles: Lint, household dust, pollen, dust mites, pet dander and mold spores Replacement frequency: 90-days of use RATING 2 PACK Coleman-Mach Climate Control Accessories AIR FILTERS STANDARD Precision, press-fit alignment to Coleman-Mach ducted ceiling assemblies Size: 16.6"x 6" Mesh Filter Fabric Captures large particles: Lint and pollen Replacement frequency: 90-days of use 2 PACK Coleman-Mach Climate Control Accessories AIR FILTERS STANDARD Precision, press-fit alignment to Coleman-Mach ducted ceiling assemblies Size: 16.6"x 6" Mesh Filter Fabric Captures large particles: Lint and pollen Replacement frequency: 90-days of use 2 PACK Coleman-Mach Climate Control Accessories SOFT START KIT Designed specifically for ALL Coleman-Mach Roof-Mounted Air Conditioners or Heat Pumps • Reduces AC compressor starting amperage up to 75% depending on AC model • Start and Run AC with less risk of tripping breakers • Requires less starting current - great for off grid applications • Ready to install Continuous Learning Feature: • The continuous learning feature allows the soft start to optimize a range of electrical parameters to work with varying load conditions. Its activation at the beginning of every start ensures the motor always operates within ideal settings. 67$57,1* $036 7,0( :,7+287 SOFT START :,7+ COLEMAN-MACH SOFT START 5('8&( 67$57 83 $03(5$*( 1($5/< CONTROL PACKAGES 9330C755 For Heat Ready Ceiling Assemblies Cool Only, Heat Ready For Cool Only Ceiling Assemblies - Cool Only Assemblies - Cool Only, Control Kit , Control Kit (Image not available) 8335A5261 0HGLXP 3UR¿OH MACH 3800, 7000, 8000, 4800 Series - Textured White 8335A5291 0HGLXP 3UR¿OH MACH 3800, 7000, 8000, 4800 Series - Textured Black 0HGLXP 3UR¿OH MACH 3800, 7000, 8000, 4800 Series - Polished White 0HGLXP 3UR¿OH MACH 3800, 7000, 8000, 4800 Series - Polished Black 0HGLXP 3UR¿OH MACH 3800, 9000 and 4900 Series - Textured White 0HGLXP 3UR¿OH MACH 3800, 9000 and 4900 Series - Textured Black 0HGLXP 3UR¿OH MINI-MACH 6700 Series - Textured White MACH 10 / 3500 Series - Textured White /RZ 3URILOH /RZ 3URILOH MACH 10 / 3500 Series - Textured Black MACH 10 / 3500 Series - Polished White /RZ 3URILOH /RZ 3URILOH MACH 10 / 3500 Series - Polished Black 8OWUD /RZ 3URILOH MACH 8 Plus / 3700 Series - Textured White 8OWUD /RZ 3URILOH MACH 8 Plus / 3700 Series - Textured Black Air Conditioners and Heat Pumps feature a 2-YEAR Limited Warranty ELECTRIC HEAT STRIPS Electric heat kit for heat ready ceiling assemblies. 382034551 )RUXVHZLWK [[[DQG [[[ 0HGLXP3URLOH DQG [[[DQG [[[ /RZ 3URILOH 6HULHV $LU &RQGLWLRQHUV DQG +HDW 3XPSV 372034551 )RU XVH ZLWK [[[ DQG [[[ 8OWUD /RZ 3UR ILOH 6HULHV $LU &RQGLWLRQHUV DQG +HDW 3XPSV CEILING ASSEMBLIES $OO &HLOLQJ $VVHPEOLHV DUH ORZ SUR¿OH )HDWXUHV LQFOXGH IURQW DQG UHDU GDPSHUV DQG SRS RXW UHWDLQHU JULOOHV ZLWK ZDVKDEOH ¿OWHUV 121 '8&7(' Smart Comfort. Control your RV’s climate from your phone with the RV Climate app. Set your temp and relax. AUTO mode takes care of the rest, turning the fan off when it’s just right. • Omni-Directional Louvers • Back-Lit LCD & Keypad Cool Only :KLWH Heat Ready :KLWH %/8(7227+ +HDW 6WULS 5HDG\ 121 '8&7(' ( Cool Only :KLWH 9430A717 Cool Only %ODFN 9630A715 Heat Pump :KLWH '(/8;( )5(( '(/,9(5< :$// 7+(50267$7 &21752//(' 3/(180 KIT +HDW 6WULS 5HDG\ 121 '8&7(' Kit :KLWH Kit %ODFN :DOO WKHUPRVWDW DQG FRQWURO SDFNDJH UHTXLUHG IRU LQVWDOODWLRQ 94304552 )5(( '(/,9(5< '(/8;( &+,//GrilleTM* )5(( 'HOLYHU\ 121 '8&7(' ( Cool Only Heat Strip Ready :KLWH Wall TStat Controlled* :KLWH :DOO WKHUPRVWDW DQG FRQWURO SDFNDJH UHTXLUHG IRU LQVWDOODWLRQ &+,//GrilleTM* '8&7(' 21/< Straight-thru in roof ducting, front/rear air discharge 8430A633 Cool Only :KLWH 8430A634 Cool Only %ODFN 8430A635 Heat Ready :KLWH 8430A6301 No Control Box :KLWH Tap. Swipe. Stay in the know. REPLACEMENT SHROUDS REPLACEMENT AIR FILTER SETS 83*5$'( WR D EHWWHU EUHDWKLQJ H[SHULHQFH ZLWK 0(59 DLU ILOWHUV MERVE 6 REPLACEMENT FILTERS 6HW RI 0(59 UDWHG ¿OWHUV 'XFWHG 6HW RI 0(59 UDWHG ¿OWHUV 1RQ GXFWHG 6LQJOH SDFN ´[ ´ 0HUY UDWHG ¿OWHU STANDARD MESH REPLACEMENT FILTERS 6HW RI PHVK ¿OWHUV 'XFWHG 6HW RI PHVK ¿OWHUV 1RQ GXFWHG SOFT START KIT 5HGXFHV LQUXVK FXUUHQW DQG VWDUWXS DPSV E\ XS WR KHOSLQJ \RXU $& VWDUW VPRRWK ² HYHQ RQ OLPLWHG SRZHU Soft Start Kit For ALL Coleman-Mach Air Conditioners and Heat Pumps
RkJQdWJsaXNoZXIy MTI2MTky