2025 Marine Catalog

GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEMS ARE STOCKED IN OUR WAREHOUSES BASED ON REGIONAL DEMAND. IF AN ITEM IS NOT IN STOCK AT A LOCAL WAREHOUSE, ADDITIONAL CHARGES MAY APPLY. u - WARNING Cancer Causing See www.P65Warnings.ca.gov v - WARNING Reproductive Harm w - WARNING Cancer and Reproductive Harm 1066 SECTION VENTILATION Item# Mount GPM Inlet Outlet Volts List Liquid Cooled Motor 843-9108516642c LC2CPMD 5 3/ 8" FPT & 3/ 4" MPT 1/ 4" MPT 115 460.39 EA 843-9108516644c LC3CPMD 8.5 3/ 4" FPT 1/ 2" MPT 115 536.29 EA 843-9108516645c LC3CPMD 8.5 3/ 4" FPT 1/ 2" MPT 230 577.49 EA 843-9108690301c(LK) LC5CPMD 14.5 1" FPT 1/ 2" MPT 115 1117.39 EA 843-9108690330c LC5CPMD 14.5 1" FPT 1/ 2" MPT 230 1265.49 EA Air Cooled Motor 843-9108500055c(LK) AC5CMD 17 1" FPT 1/ 2" MPT 115 556.39 EA Repl. Parts Description Fits List 843-725115006(LK) Wet End Assembly LC-3C 303.49 EA Provides seawater circulation for marine air conditioning systems. The magnetic drive eliminates the mechanical shaft seal. The impeller and drive magnets are strong, permanent ceramic types, which prevent slippage, insuring that full motor power is converted into pumping power. Requires a flooded inlet and must be mounted below the waterline. Includes a 6' power cord. "LC" models are totally enclosed liquid-cooled motors, and can be run in open air or submerged. "AC" models have air-cooled, open drip-proof motors and must be in a dry environment. SEAWATER A/C PUMP - FROM DOMETIC LC2CPMD LC5CMD/CPMD LC3CPMD AC5CMD Item# GPM Ports List 34-CP20c 17 Inlet: 3/ 4" NPT/Outlet: 1/ 2" NPT 428.00 EA Ideal for baitwell or any onboard pumping job that needs high flow and low pressure. Includes garden hose adapter. Motor is ignition protected. Includes an adapter for garden hose conection. NOT TO BE USED IN POTABLE WATER SYSTEMS. CENTRIFUGAL PUMP Item# GPM Ports Volts List 6-436977a(K) 11 1/ 2" Male NPT 110 446.09 EA 6-436979a(K) 14 1/ 2" Male NPT 110 496.79 EA 6-436981a(LK) 21 3/ 4" Male NPT 110 533.19 EA Designed for applications that require a safe and leak free, continuous duty pump. Great for marine air conditioning circulation, ice makers, hot water circulation, livewell and bait tank installations. Pump head is manufactured in chemical resistant thermoplastics and uses SS fasteners. UL listed, ignition and thermally protected fan cooled motor. NEMP SERIES MAG-DRIVE CENTRIFUGAL PUMP Item# GPM Volts List 275-4758172A80c 4.5 115 VAC 520.09 EA Self-priming Circulation Pumps help prevent air locking and keep your air conditioning system up and running. Designed with automatic demand. Operated quietly and includes thermal protection. 50 psi bypass. EPDM valves. MARINE AIR CONDITIONING CIRCULATION PUMP Item# Inlet Outlet Volts List 836-5011372B(LK) 1" FPT 1/ 2" MPT 115 538.49 EA Magnetically driven marine coolant pump with no shaft seal and Open Drop Proof motor. Hardened Carbon bushing allows for extended run dry time without damage to the pump head. KOOL AIR PM 1000 • Heat pump reverse cycle operation • 41° F temperature fluctuation • Compressor noise and vibrations almost zero • No current peaks during start-up • Overall reduction of electricity consumption • Constant Flow technology fan • Twin Rotary compressors • Constant temperature of the air flow • New wall touch display • WIFI remote control via smartphone allows you to reach, monitor and set-up your unit through the dedicated Velair app. VSD SMART Self-contained-VSD air conditioners provides the best of the existing technology: compressor with brushless DC motor and inverter that constantly controls speed and delivered cooling power (Variable Speed Drive); reverse blade brushless fan; electronic expansion valve; R32 refrigerant. VSD INVERTER SELF CONTAINED AIR CONDITIONING UNIT Item# Model Volts BTUs List 216-24831GUva Compact i10 VSD Smart 115 4.000 - 10.000 BTU 3681.69 EA 216-24832JUa(LW) Compact i16 VSD Smart 115 6.000 - 16.000 BTU 3952.89 EA Bilge/Engine Heaters • Ignition protected design • Dual airflow redundancy • Omnidirectional airflow discharge • Safe hermetically sealed thermostat • Quick release bracket included • 20' power cord The use of Pali is not a substitute for properly winterizing your boat. Extend the boating season and protect your engine against cold snaps prior to winterization. Utilizes a selfregulating PTC heating element that cannot overheat. It meets all ignition protection guidelines and standards to allow it to be safely used in the marine engine compartment. Automatically activates when the engine compartment temp drops to 41°F (5°C). The only heater of its type fully safety compliant to UL and CSA standards. PALI 120V ENGINE HEATER Item# Size Volts Color List 141-9510CABBX(K) 9" L X 5" W x 413/ 16" H 120 Black 349.99 EA Item# Inlet Outlet Volts List 836-5011370B(LK) 3/ 4" 1/ 2" 115 480.19 EA Fully submersible, magnetically driven pump with no shaft seal. Pump is epoxy encapsulated allowing the pump to run fully submerged. KOOL AIR PM 500

RkJQdWJsaXNoZXIy MTI2MTky