2025 Marine Catalog

GENERAL BOATING WATERSPORTS & BOATS SEATING COVERS/TOPS MAINTENANCE ELECTRICAL HARDWARE PLUMBING PROPS & ANODES FUEL ELECTRONICS & NAVIGATION SAFETY TROLLING & FISHING ANCHORING/ MOORING TRAILERING PAINT VENTILATION FASTENERS STEERING ENGINE ITEM NUMBERS IN RED ARE HAZARDOUS ITEMS IN BLUE ARE NEW ] SEA VALUE v OVERSIZED d UPS/FEDEX SURCHARGE (L) = SE & MIDWEST ONLY (K) = NE & MID-ATLANTIC ONLY (W) = WEST COAST ONLY u - WARNING Cancer Causing See www.P65Warnings.ca.gov v - WARNING Reproductive Harm w - WARNING Cancer and Reproductive Harm SECTION 1173 PLUMBING Item# Volts List 29-7700Da 12 Volts 626.99 EA Ideal for fast evacuation of water from a vessel. The Evacuator is comprised of two 4,000 GPH (15,141 LPH) pumps in tandem, with a net volume at open discharge of 7,700 GPH (29,148 LPH). Useful for non-marine applications as well, including dewatering flooded basements, swimming pools, or excavations, the Rule Evacuator is a great alternative to gas-powered pumps. The Evacuator simply connects to a 12V battery. A 3-inch discharge hose is required in this application. • Built in back up allows each pump to operate independently, if necessary • Long power lead at 7 ft. ideal for setting up quick connections to power • Each pump independently wired; 25 amp fuse each recommended • Portable; can easily be moved from boat to boat EVACUATOR ULTILITY PUMP Item# Description List 6-118300000c(K) End cover fits 11810 DC pump 32.19 EA 6-25740000c(K) Wear Plate 47.49 EA 6-8900000(K) Gasket / O-Ring 10.49 EA 6-900920004c Service Kit Nitrile 77.29 PK SERVICE PARTS 118310000 900920004 Circulation and Air Conditioning Pumps Item# Mount GPM Inlet Outlet Volts List Liquid Cooled Motor 843-9108516642c LC2CPMD 5 3/ 8" FPT & 3/ 4" MPT 1/ 4" MPT 115 460.39 EA 843-9108516644c LC3CPMD 8.5 3/ 4" FPT 1/ 2" MPT 115 536.29 EA 843-9108516645c LC3CPMD 8.5 3/ 4" FPT 1/ 2" MPT 230 577.49 EA 843-9108690301c(LK) LC5CPMD 14.5 1" FPT 1/ 2" MPT 115 1117.39 EA 843-9108690330c LC5CPMD 14.5 1" FPT 1/ 2" MPT 230 1265.49 EA Air Cooled Motor 843-9108500055c(LK) AC5CMD 17 1" FPT 1/ 2" MPT 115 556.39 EA Repl. Parts Description Fits List 843-725115006(LK) Wet End Assembly LC-3C 312.59 EA Provides seawater circulation for marine air conditioning systems. The magnetic drive eliminates the mechanical shaft seal. The impeller and drive magnets are strong, permanent ceramic types, which prevent slippage, insuring that full motor power is converted into pumping power. Requires a flooded inlet and must be mounted below the waterline. Includes a 6' power cord. "LC" models are totally enclosed liquid-cooled motors, and can be run in open air or submerged. "AC" models have air-cooled, open drip-proof motors and must be in a dry environment. SEAWATER A/C PUMP - FROM DOMETIC LC2CPMD LC5CMD/CPMD LC3CPMD AC5CMD Item# GPM Ports List 34-CP20c 17 Inlet: 3/ 4" NPT/Outlet: 1/ 2" NPT 428.00 EA Ideal for baitwell or any onboard pumping job that needs high flow and low pressure. Includes garden hose adapter. Motor is ignition protected. Includes an adapter for garden hose conection. NOT TO BE USED IN POTABLE WATER SYSTEMS. CENTRIFUGAL PUMP Item# GPM Ports Volts List 6-436977a(K) 11 1/ 2" Male NPT 110 446.09 EA 6-436979a(K) 14 1/ 2" Male NPT 110 496.79 EA 6-436981a(LK) 21 3/ 4" Male NPT 110 533.19 EA Designed for applications that require a safe and leak free, continuous duty pump. Great for marine air conditioning circulation, ice makers, hot water circulation, livewell and bait tank installations. Pump head is manufactured in chemical resistant thermoplastics and uses SS fasteners. UL listed, ignition and thermally protected fan cooled motor. NEMP SERIES MAG-DRIVE CENTRIFUGAL PUMP Item# GPM Volts Amps List 6-508400012]a 29 12 9 579.99 EA These heavy duty, quiet running pumps feature a stainless steel body, long-life motor and mechanical seal, and an anti-clogging impeller design. Rated for continuous duty and the high pressure for a duty cycle of maximum 30 minutes on with minimum 30 minutes off. ISO 8846 Marine ignition protected. Configured with 3/ 4" Female NPT port threading. 4.4" H x 4.5" W x 6.3" L. CYCLONE SERIES CENTRIFUGAL PUMPS Magnetically driven, small footprint centrifugal pump for continuous operation can move up to 60% glycol and water mixture. Can run dry for up to 30 min. Consistent flow rates with low power consumption, it is waterproof and dustproof. For heating and cooling systems on boats, RV's and auto applications and is a direct replacement for OEM intercooler circulation pumps. Item# Description GPM Ports Volts List 189-102450103c CM10P7-1 4 5/ 8" 12 208.39 EA 189-102448603c CM10P7-1 w/Cord 4 5/ 8" 12 208.39 EA 189-102450203c(LK) CM10P7-1 5 3/ 4" 12 228.19 EA 189-102448703c(LW) CM10P7-1 w/Cord 5 3/ 4" 12 228.19 EA 189-102448803c CM30P7-1 w/Cord 5.3 5/ 8" 12 228.19 EA 189-102450403c CM30P7-1 6.9 3/ 4" 12 228.19 EA CM30 CM MAG DRIVE CIRCULATING PUMP Item# List 47-31601 348.39 EA Replaces: 46-862914A13. Uses impeller 18-3016-1 MERCRUISER SEA WATER PUMP - BRASS

RkJQdWJsaXNoZXIy MTI2MTky