ITEM NUMBERS IN RED ARE HAZARDOUS ITEMS IN BLUE ARE NEW v OVERSIZED d UPS/FEDEX SURCHARGE u - WARNING Cancer Causing See www.P65Warnings.ca.gov v - WARNING Reproductive Harm w - WARNING Cancer and Reproductive Harm AWNINGS & ACCESSORIES CAMPSITE LIVING GENERAL ACCESSORIES ROOFING & SEALANTS SANITATION HEATING & COOLING GRILLING & CAMPWARE HOUSEWARES CLEANERS & WAXES FRESH WATER GENERATOR & POWER SOLUTIONS APPLIANCES LIGHTING HARDWARE SERVICE & MAINTENANCE STEPS & TIEDOWNS TOWING & HITCHES ELECTRICAL ELECTRONICS VENTS CARRIERS & COVERS JACKS & LEVELERS LP GAS ELECTRICAL 445 Item# Description 661-5032 12 circuits Two isolated 6-circuit fuse blocks with a negative bus. For use when a mix of switched and 24-hour circuits are desired in the same block. • Common and/or independent source fuse block • For use with either two isolated batteries or with a single battery • Clear insulating cover satisfies ABYC/USCG requirements • Easy to open, push button latch • Tin-plated copper buses and fuse clips • Includes 20 write-on circuit labels • Fuses sold separately Specifications • Voltage Max.: 32V DC • Amperage Max.: 30A per circuit 100A total • Fuse Type: ATO® or ATC® • Screw Terminal: #8-32 Screws ST BLADE SPLIT BUS FUSE BLOCK Item# Description Terminals 661-5045 4 Circuit w/Cover #8-32 661-5046 8 Circuit w/Cover #8-32 Provides surface mount circuit protection for ATO®/ATC® Fuses in a compact footprint. The single side design allows wire entry from one side to maximize space. • Common source fuse block • Ignition Protected • Insulating cover meets ABYC/USCG requirements • Tin-plated copper connections • Small format labels available • Fuses sold separately Specifications: • Voltage Max.: 32V DC • Amperage Max.: 30A per circuit • Amperage Max.: 100A per block ST BLADE COMPACT FUSE BLOCK - COMMON SOURCE 5045 5046 Item# Amps Stud Size 661-5007100 110-200A 1/ 4"-20 (M6) Up to 4/ 0 AWG 661-5502100 225-400A 5/ 16"-18 (M8) Up to 4/ 0 AWG Opt. Accy. Amps Size Fuse 661-5112 110A 2.44"L x 1.06"W A3T • Four stud design for ample access • Insulating cover satisfies ABYC/USCG requirements • Cover breakouts allow wire access in any direction • Stud design ensures secure fuse mounting • Stainless steel studs provide resistance to corrosion • Safe & secure one-piece stainless flange nuts • UL 94-V0 base resists high heat Allows the use of Class T fuses for fast acting circuit protection of inverters and other electronics. CLASS T FUSE BLOCK WITH INSULATING COVER 5007100 5502100 • For ATO/ATC fuses • Interlocking modules snap together • 1/ 4" tin plated copper tab terminals • Rated 30 Amp per circuit, 160 amp max for block Item# Gangs Fuse Neg Bus Size 11-FS40430 4 ATO/ATC Yes 31/ 2" x 31/ 4" 11-FS40420 6 ATO/ATC Yes 33/ 4" x 31/ 4" 11-FS40450 8 ATO/ATC Yes 41/ 2" x 31/ 4" 11-FS40740 10 ATO/ATC Yes 5" x 31/ 4" 11-FS40440 14 ATO/ATC Yes 61/ 4" x 31/ 4" 11-FS40410 14 ATO/ATC No 51/ 2" x 31/ 4" 10-Gang 14-Gang 8-Gang 4-Gang 6-Gang ATO/ATC FUSE BLOCK 100A ATO® fuse blocks feature an integrated negative busbar and includes a sheet of circuit identification labels. SD ATO® and SD MINI® fuse blocks feature LED blown fuse indication. • Snap-on insulating cover (included) • Screw termination • Fuses sold separately • 32V DC max • Continuous current rating: 100A ST ATO® fuse block features an integrated negative busbar and includes a sheet of circuit identification labels.LED blown fuse indicator MINI fuse block with LED blown fuse indicator FUSE BLOCK 880027 ATO 880024 MINI 880028 ATO 880025 MINI 880026 MINI 880023 SD ATO 880021 SD ATO 880022 SD ATO Item# Gangs Description Fuse Neg Bus Type List 12-880021BPb 4 w/ LED ATO No SD 45.19 EA 12-880022BPb 6 w/ LED ATO No SD 59.19 EA 12-880023BPb 10 w/ LED ATO No SD 73.59 EA 12-880027BPb 6 ATO Yes ST 108.49 EA 12-880028BPb 12 ATO Yes ST 122.99 EA 12-880024BPb 4 w/ LED MINI No SD 45.19 EA 12-880025BPb 6 w/ LED MINI No SD 55.59 EA 12-880026BPb 10 w/ LED MINI No SD 72.49 EA
RkJQdWJsaXNoZXIy MTI2MTky